TOMY Autoclave FLS-1000
 

Autoclave is essential for almost any type of laboratory, and it is crucial to choose the best autoclave that suits your needs.
Secure Sterilization and Time-saving are the high priority to consider for researchers, and TOMY Autoclaves are designed with innovative features as standard.

Secure Sterilization
Standard Fine Pressure Adjustment

Secure Sterilization condition is created by saturated steam that temperature and pressure keep the balance for a certain time.
TOMY Autoclaves heat water in the chamber and create steam. The generated steam is discharged with air from the chamber to approach the saturated steam condition.
When air remains in the chamber, the balance of temperature and pressure breaks and it makes pressure rise.
Fine Pressure Adjustment monitors temperature and pressure, works automatically to remove residual air from the chamber, and adjusts pressure to approach ideal condition for more effective sterilization.


 

Time-saving

Cooling Fan System


TOMY Autoclaves are standard-equipped with a dual-fan cooling system, shortening overall operation time. The Cooling Fan System reduces cooling time by 60 min.* compared to non-fan operation. It will save your time and give you more to focus on other things.


* In the case of FLS-1000 under the test condition of no load operation, room temperature 25 C, sterilizing water 6 liters and power input AC200V 18A.

To Choose the Best Autoclave

Choosing the best autoclave largely depends on several factors, including articles to be sterilized (what you are autoclaving), your throughput needs (how large your articles to be sterilized are and how much you need to autoclave) and available laboratory space, as well as convenience and personal preference. TOMY Autoclave line- up will help you choose the right autoclave for your sterilizing needs.

High-throughput Autoclave
FLS-1000

  • Large volume of liquid sterilization like water, media or solvent
  • Bioreactor and fermenter sterilization
  • Animal cage sterilization.

Multiple Shared Use Autoclave SX-series

  • For central autoclave room and washing room
  • For shared use among some laboratories
  • Both purpose for preparation of labwares and decontamination of labwastes

Biohazardous Waste Autoclave
SX-700BH / 500BH

  • Next to biosafety cabinet
  • Immediate sterilization after bench-work
  • Decontamination before disposal of biowaste

Easy Fast Autoclave
ASX-500

  • Entry model
  • Simple operation
  • Dedicated to sterilize solid articles like labwares or labwastes

Autoclave & Accessories Selection Guide

Model FLS-1000 SX-700 SX-500 SX-300 SX-700BH SX-500BH
High-throughput Autoclave FLS-1000
→
Multiple Shared Use Autoclave SX-series
→
Biohazardous Waste Autoclave SX-700BH / 500BH
→
Fine Pressure Adjustment Yes Yes Yes Yes Yes Yes
Cooling Fan Yes Yes Yes Yes Yes Yes
Ergonomic Height Design(Height to working table)

Yes

 

(78.5 cm)

Yes

 

(82.7 cm)

Yes

 

(79.4 cm)

Yes

 

(61.4 cm)

Yes

 

(82.7 cm)

Yes

 

(79.4 cm)

Sterilization Course Sterilization – Normal

 

(Labware and Waste)

Yes Yes Yes Yes Yes Yes
Sterilization – Liquid

 

(Media, Solvent and Water)

Yes Yes Yes Yes Yes Yes
Sterilization & Warming

 

(Sterilizing and keep
warming media)

  Yes Yes Yes Yes Yes
Warming

 

(Melting and keep warming
media)

  Yes Yes Yes Yes Yes

Option

 

High Altitude
Sterilization Program*1

→

until 616 hPa or higher

 

(equivalent to an altitude of
4,000m)

  Yes Yes Yes Yes Yes
until 750 hPa or higher

 

(equivalent to an altitude of
2,000m)

Yes

 

(Standard)

Yes Yes Yes Yes Yes

Exhaust through HEPA filter (Bio Box)

 

→

        Yes Yes
Option

External Temperature Sensor

→

Yes Yes Yes Yes Yes Yes
Option

Printer

→

Yes

 

(Dot Matrix)

Yes

 

(Thermal)

Yes

 

(Thermal)

Yes

 

(Thermal)

Yes

 

(Thermal)

Yes

 

(Thermal)

Option

 

Biowaste Sterilization
Container ST-ZERO

Biowaste Sterilization Container ST-ZERO

→

Yes Yes Yes Yes Yes Yes

Option

 

Separator Kit for disposal
petri dish

Separator Kit for disposal petri dish

   

Separator
Kit 500

     
Option

Flask Stand for 5L × 4 flasks

→

Yes          

Basket

Basket

Model ACA-1000B ACA-700B ACA-315B ACA-315B ACA-700B ACA-315B
Standard equipped
number per unit
2 2 2 1 2 2
Max. loaded number
per unit
2 3 3 2 3 3
Size of basket φ 415
×
233 H mm
φ 345
×
181 H mm
φ 300
×
181 H mm
φ 300
×
181 H mm
φ 345
×
181 H mm
φ 300
×
181 H mm
Max. loaded number of
500ml bottle per basket*2
17 10 8 8 10 8
Max. loaded number of
500ml flask per basket
10*2 7 5 5 7 5
Option

Long Basket

Long Basket

Model ACA-1000TP ACA-710TP ACA-325TP ACA-310TP ACA-710TP ACA-325TP
Option

Sterilizing Bag

Sterilizing Bag

Model   DAB-700 DAB-321 DAB-321 DAB-700 DAB-321
Option

Bucket

Bucket

Model ACA-1000K ACA-700K ACA-315K ACA-315K ACA-700K ACA-315K
* 
1 Operating temperature range will be changed after installed / selected the high altitude program.
* 2 Refer to the information of Loading Capacity.
* For SX-700E / 500E / 300E (CE marked), refer to the individual page for SX-700E / 500E / 300E or contact us.

Autoclaves Specifications List

Model FLS-1000 SX-700 SX-500 SX-300 SX-700BH SX-500BH
High-throughput Autoclave FLS-1000→ Multiple Shared Use Autoclave SX-series→ Biohazardous Waste Autoclave SX-700BH / 500BH→

220V
model

230V
model

240V
model

230V
model
(220 to 240V)

120V model
230V model (220 to 240V)

230V model
(220 to 240V)

120V model
230V model
(220 to 240V)

Temperature
Setting Range
Sterilizing 105 to 123? *1 105 to 135? *1 105 to 135? *1
Heating 45 to 104? 45 to 104?
Warming 45 to 95? *1 45 to 95? *1
Maximum Operating Pressure 0.193 MPa 0.250 MPa 0.263 MPa 0.250 MPa 0.263 MPa
Time Setting
Range
Sterilizing 0:01 to 9:59 / 1 to 99 hours /
1 to 999 minutes / 0:01 to 9:59,
10 to 99 hours (Selectable)
0:01 to 9:59 / 1 to 99 hours /
1 to 999 minutes / 0:01 to 9:59,
10 to 99 hours (Selectable)
0:01 to 9:59 /
1 to 99 hours /
1 to 999 minutes /
0:01 to 9:59,
10 to 99 hours (Selectable)
Heating
Warming 1 to 99 hours 1 to 99 hours
Display Temperature Digital Digital Digital
Pressure
Gauge
Analog Analog Analog
0 to 0.4 MPa 0 to 0.4 MPa 0 to 0.4 MPa
Time Digital Digital Digital
Safety Devices Safety Valve
Lid Interlock
Leakage Breaker
No Water Heating Prevention
Over-temperature Prevention
Over-pressure Prevention
Temperature Sensor
Malfunction Detection
Pressure Sensor Malfunction Detection
Exhaust Valve Malfunction Detection
Low Sterilizing Water Level Detection
Chamber Lid Open / Close Detection
Drain Access Cover Open Detection
Exhaust Tank Full Level Detection
Safety Valve
Lid Interlock
Leakage Breaker
No Water Heating Prevention
Over-temperature Prevention
Over-pressure Prevention
Temperature Sensor
Malfunction Detection
Pressure Sensor Malfunction Detection
Exhaust Valve Malfunction Detection
Low Sterilizing Water Level Detection
Chamber Lid Open / Close Detection
Exhaust Bottle Detection
Safety Valve
Lid Interlock
Leakage Breaker
No Water Heating
Prevention
Over-temperature
Prevention
Over-pressure
Prevention
Temperature Sensor
Malfunction Detection
Pressure Sensor
Malfunction Detection
Exhaust Valve
Malfunction Detection
Low Sterilizing
Water Level Detection
Chamber Lid
Open / Close Detection
Exhaust Bottle Detection
Chamber Dimensions
(mm)
φ 450 × 678 φ 370 × 774 φ 325 × 733 φ 325 × 553 φ 370 × 774 φ 325 × 733
Capacity 100 L 79 L 58 L 44 L 79 L 58 L
Material SUS304 (Stainless Steel) SUS304 (Stainless Steel) SUS304 (Stainless Steel)
Main Body Dimensions
(mm)
(Excluding
protruding)
600W × 600D × 940H 470W
×
528D
×
1,003H
410W
×
477D
×
970H
410W
×
477D
×
790H
470W
×
528D
×
1,003H
(Bio Box:
φ215 × 525 H)
410W
×
477D
×
970H
(Bio Box:
φ215 × 525 H)
Net Weight 108 kg 72 kg 60 kg 50 kg 72 kg
(Bio Box: 5 kg)
60 kg
(Bio Box: 5 kg)
Power Requirements AC220V
50 / 60Hz
15A 1P
AC230V
50 / 60Hz
15A 1P
AC240V
50 / 60Hz
15A 1P
AC230V
50 / 60Hz
15A 1P
AC120V
50 / 60Hz
20A 1P
AC230V
50 / 60Hz
15A 1P
AC120V
50 / 60Hz
15A 1P
AC230V
50 / 60Hz
10A 1P
AC230V
50 / 60Hz
15A 1P
AC120V
50 / 60Hz
20A 1P
AC230V
50 / 60Hz
15A 1P
Standard Basket Stainless Steel Basket
( φ 415 × 233 mm)
2 pcs
Stainless
Steel
Basket
( φ 345
×
181 mm)
2 pcs
Stainless
Steel
Basket
( φ 300
×
181 mm)
2 pcs
Stainless
Steel
Basket
( φ 300
×
181 mm)
1 pc
Stainless
Steel
Basket
( φ 345
×
181 mm)
2 pcs
Stainless
Steel
Basket
( φ 300
×
181 mm)
2 pcs
Compliance of Standard IEC 61010-2-040, IEC61326-1

* 1. Max. operating temperature will be changed for the high altitude sterilization program and it depends on the altitude level.
* For SX-700E / 500E / 300E (CE marked), refer to the catalog on the individual page for SX-700E / 500E / 300E or contact us.